Find the submittal datasheet for any FRENIC drive: choose the series and supply, then the duty, motor kW and IP rating. Download a datasheet directly, or add up to 15 to a list and download them together as one ZIP. Downloads are limited to 100 files per hour.

Which duty do I need?
DutyOverloadMax. ambientTypical applications
ND Normal Duty120% for 1 min40 °CFans, pumps, wire drawing
HD Heavy Duty150% for 1 min40 °CVertical conveyance
HND High-carrier Normal Duty120% for 1 min50 °CFans, pumps, wire drawing
HHD High-carrier Heavy Duty150% for 1 min, 200% for 0.5 s50 °CVertical conveyance, winding and printing machines

Ratings as per the Fuji Electric FRENIC-Ace catalogue; MEGA uses HND/HHD on the same basis. Above the maximum ambient the drive must be derated. A few small HND models (Ace 0007/0012 400V and Ace E3 single-phase) are limited to 40 °C. Mini C2 (listed under HD) and eHVAC (listed under ND) are rated up to 50 °C. HVAC (listed under ND, 110% for 1 min) is rated 50 °C in IP21 and 40 °C in IP55. Always check the ambient temperature on the datasheet.

ModelSeriesSupplyDutykWRated AIP
Loading…

Datasheets are prepared by Trubros from Fuji Electric catalogue data for reference and selection. Please confirm final ratings with the manufacturer's catalogue or contact us.